Extensometers for Compression, Flexure and Components Testing
Download- Various
- Ambient temperature
- Plastic
- Wood
- Fiber-reinforced composites
- Compression test
- Flexure test
- Components testing
Reliable and accurate determination of deflection, deformation and settling behavior
A very important factor in obtaining reliable test results is to ensure minimum influence of the displacement transducer on the test. The ZwickRoell displacement transducer ensures reliable test results through secure attachment, precise axial alignment and tracking, and a small increase in contact force that does not affect the test process or the test results.
The displacement transducer measures with high accuracy, independent of the test temperature. All temperature-related accuracy deviations are automatically compensated in every ZwickRoell testing machine.
Deformation measurement on a damper using the T15 displacement transducer
Extensometers for compression tests, flexure tests and components tests should have minimal influence on the test in order to achieve reliable test results.A simple and effective option for these tests is the T15 displacement transducer shown here.
Technical overview
Description | Value | |
Type | Displacement transducer T15 | |
Item No. | 1090621 | |
Dimensions | ||
Length | 154 | mm |
Height | 65 | mm |
Depth | 37 | mm |
Measurement displacement | 15 | mm |
Contact force, min. | 0.06 | N |
Spring rate | 0.0106 | N/mm |
Accuracy class | ||
To ISO 9513 | 1 | |
To ASTM E83 (based on: 50 mm gauge length) | B2 | |
Ambient temperature | -70 ... +200 | °C |
Minimum version | testXpert III V 1.6 | |
Weight | 120 | g |
Compression test option | Available | |
Scope of delivery | ||
Displacement transducer | 1 | piece(s) |
Storage case | 1 | piece(s) |
Description | Value | |
Type | Displacement transducer T25 | |
Item No. | 1091765 | |
Dimensions | ||
Length | 221 | mm |
Height | 65 | mm |
Depth | 37 | mm |
Measurement displacement | 25 | mm |
Contact force, min. | 0.18 | N |
Spring rate | 0.0057 | N/mm |
Accuracy class | ||
To ISO 9513 | 1 | |
To ASTM E83 (based on: 50 mm gauge length) | B2 | |
Ambient temperature | -70 ... +200 | °C |
Minimum version | testXpert III V 1.6 | |
Weight | 126 | g |
Compression test option | Not available | |
Scope of delivery | ||
Displacement transducer | 1 | piece(s) |
Storage case | 1 | piece(s) |
Description | Value | |
Type | Displacement transducer T50 | |
Item No. | 1091766 | |
Dimensions | ||
Length | 311 | mm |
Height | 65 | mm |
Depth | 37 | mm |
Measurement displacement | 50 | mm |
Contact force, min. | 0.09 | N |
Spring rate | 0.0024 | N/mm |
Accuracy class | ||
To ISO 9513 | 1 from 0.5 mm | |
To ASTM E83 (based on: 50 mm gauge length) | B2 | |
Ambient temperature | -70 ... +200 | °C |
Minimum version | testXpert III V 1.6 | |
Weight | 126 | g |
Compression test option | Not available | |
Scope of delivery | ||
Displacement transducer | 1 | piece(s) |
Storage case | 1 | piece(s) |